Fuse 22x58 500V aM 80A

442080.0.0
DF
Available
Class
aM
Rated current In (A)
80
Rated Voltage Un AC (V)
500
Rated break.capacity I1 AC (A)
80000
Voltage of total I2t test
500
Format
Cylindrical
Dimension
22x58mm
Homologations
IEC
Power loss (W)
5,86

Fuse 22x58 690V aM 63A

442063.0.0
DF
Available
Class
aM
Rated current In (A)
63
Rated Voltage Un AC (V)
690
Rated break.capacity I1 AC (A)
80000
Voltage of total I2t test
690
Format
Cylindrical
Dimension
22x58mm
Homologations
IEC
Power loss (W)
4,46

Fuse 22x58 690V aM 50A

442050.0.0
DF
Available
Class
aM
Rated current In (A)
50
Rated Voltage Un AC (V)
690
Rated break.capacity I1 AC (A)
80000
Voltage of total I2t test
690
Format
Cylindrical
Dimension
22x58mm
Homologations
IEC
Power loss (W)
3,48

Fuse 22x58 690V aM 40A

442040.0.0
DF
Available
Class
aM
Rated current In (A)
40
Rated Voltage Un AC (V)
690
Rated break.capacity I1 AC (A)
80000
Voltage of total I2t test
690
Format
Cylindrical
Dimension
22x58mm
Homologations
IEC
Power loss (W)
3,4

Fuse 22x58 690V aM 32A

442032.0.0
DF
Available
Class
aM
Rated current In (A)
32
Rated Voltage Un AC (V)
690
Rated break.capacity I1 AC (A)
80000
Voltage of total I2t test
690
Format
Cylindrical
Dimension
22x58mm
Homologations
IEC
Power loss (W)
2,13

Fuse 22x58 690V aM 25A

442025.0.0
DF
Available
Class
aM
Rated current In (A)
25
Rated Voltage Un AC (V)
690
Rated break.capacity I1 AC (A)
80000
Voltage of total I2t test
690
Format
Cylindrical
Dimension
22x58mm
Homologations
IEC
Power loss (W)
1,53

Fuse 22x58 690V aM 20A

442020.0.0
DF
Available
Class
aM
Rated current In (A)
20
Rated Voltage Un AC (V)
690
Rated break.capacity I1 AC (A)
80000
Voltage of total I2t test
690
Format
Cylindrical
Dimension
22x58mm
Homologations
IEC
Power loss (W)
1,29

Fuse 22x58 690V aM 16A

442016.0.0
DF
Available
Class
aM
Rated current In (A)
16
Rated Voltage Un AC (V)
690
Rated break.capacity I1 AC (A)
80000
Voltage of total I2t test
690
Format
Cylindrical
Dimension
22x58mm
Homologations
IEC
Power loss (W)
1,21

Fuse 22x58 400V aM 125A

442015.0.0
DF
Available
Class
aM
Rated current In (A)
125
Rated Voltage Un AC (V)
400
Rated break.capacity I1 AC (A)
120000
Voltage of total I2t test
400
Format
Cylindrical
Dimension
22x58mm
Homologations
IEC
Power loss (W)
8,42

Fuse 22x58 690V aM 12A

442012.0.0
DF
Available
Class
aM
Rated current In (A)
12
Rated Voltage Un AC (V)
690
Rated break.capacity I1 AC (A)
80000
Voltage of total I2t test
690
Format
Cylindrical
Dimension
22x58mm
Homologations
IEC
Power loss (W)
0,83

Fuse 22x58 690V aM 10A

442010.0.0
DF
Available
Class
aM
Rated current In (A)
10
Rated Voltage Un AC (V)
690
Rated break.capacity I1 AC (A)
80000
Voltage of total I2t test
690
Format
Cylindrical
Dimension
22x58mm
Homologations
IEC
Power loss (W)
0,74

Fuse 22x58 690V aM 8A

442008.0.0
DF
Available
Class
aM
Rated current In (A)
8
Rated Voltage Un AC (V)
690
Rated break.capacity I1 AC (A)
80000
Voltage of total I2t test
690
Format
Cylindrical
Dimension
22x58mm
Homologations
IEC
Power loss (W)
0,73

Filter by

Manufacturer
more... less
Class
more... less
Rated Voltage Un AC (V)
32 1140
Rated Voltage Un DC (V)
400 1000
Rated current In (A)
0.16 1600
Format
more... less
Dimension
Homologations
more... less
Pre-arcing I2t value (A2s)
0.08 14000000
Total I2t value (A2s)
0.35 35000000
Product added to wishlist